Technical Guides

Siteplore Technical Guides

Field-ready guidance for trustworthy monitoring systems.

Practical engineering guidance for sensing, installation, connectivity, power monitoring, machine health, environmental measurement, data quality and commissioning.

Monitoring architectureDesign chain active
01
Measurement layerSensors, meters, signal quality, calibration and installation
Field
02
Edge & connectivityRS485, Modbus, IO-Link, MQTT, HTTPS and local buffering
Transport
03
Data & contextAsset model, timestamps, units, metadata and quality flags
Meaning
04
Analytics & responseThresholds, trends, anomaly detection, alerts and workflow
Action
05
Verification & learningInspection findings, corrective work, outcomes and feedback
Evidence
iA reliable dashboard begins with a reliable measurement chain.

How to use the guides

Follow the complete measurement lifecycle.

A technically correct sensor can still produce weak decisions if selection, installation, context, communication or verification is incomplete.

01

Define the decision and risk

Start with the asset, failure mode, operating decision, consequence and required response time.

02

Select and install the measurement

Match range, accuracy, environment, location, mounting, sampling and calibration to the use case.

03

Verify the complete data chain

Commission sensor-to-dashboard values, timestamps, scaling, units, communication loss and quality flags.

04

Operate, maintain and improve

Review alarms, inspections, calibration, corrective work and field feedback throughout the lifecycle.

Technical guide library

Find the right guide for the next engineering task.

Search by protocol, sensor, asset, measurement, outcome or implementation stage.

12 guides shown
Engineering

Selecting measurements for motors and pumps

Choose useful parameters from expected failure modes, asset criticality, operating state and required warning time.

Guide scope
  • Failure-mode-to-signal mapping
  • Continuous versus periodic measurement
  • Sensor range and environment
Practitioner

Vibration measurement points and mounting

Improve repeatability by controlling sensor location, orientation, mounting stiffness, speed and load context.

Guide scope
  • Axial, horizontal and vertical points
  • Stud, adhesive and magnetic mounting
  • Operating-condition records
ISO 20816 seriesReliability services →
Planning

Portable versus continuous machine monitoring

Use route-based screening for broad coverage and continuous monitoring where consequence or deterioration rate demands it.

Guide scope
  • Selection criteria and criticality
  • Inspection route design
  • Escalation to permanent sensing
Risk-based selectionRequest assessment →
Practitioner

Power-meter data points for useful energy monitoring

Define the electrical and contextual variables needed for consumption, demand, power-quality and loss analysis.

Guide scope
  • Core electrical measurements
  • Demand and energy intervals
  • Production and runtime context
IEC / ISO 50001 contextExplore PowerWatch →
Engineering

Energy baseline and EnPI normalization

Avoid false saving claims by accounting for production volume, product mix, weather, occupancy and operating hours.

Guide scope
  • Significant energy variables
  • Baseline boundary and period
  • Post-action verification
Field guide

RS485 and Modbus RTU field checklist

Commission stable multidrop communication by checking topology, termination, shielding, addressing and serial parameters.

Guide scope
  • Daisy-chain wiring and termination
  • Baud, parity and slave IDs
  • Error isolation and testing
Modbus implementationEdge & connectivity →
Engineering

MQTT and HTTPS telemetry architecture

Select a transport method and payload structure that can recover from field outages without losing data integrity.

Guide scope
  • Topics, payloads and timestamps
  • Store-and-forward strategy
  • TLS, identity and retry behaviour
Secure telemetryAPI & integrations →
Selection guide

Selecting an industrial edge gateway

Match interfaces, environment, buffering, diagnostics, power supply and lifecycle support to the deployment risk.

Guide scope
  • Interfaces and connectivity
  • Environmental and enclosure needs
  • Remote diagnostics and recovery
Industrial deploymentGateway solutions →
Field guide

Weather-station siting and commissioning

Reduce measurement bias through appropriate height, orientation, obstruction clearance, levelling and verification.

Guide scope
  • Siting and exposure considerations
  • Mechanical and compass alignment
  • Commissioning and data checks
Application guide

Soil-moisture deployment for irrigation decisions

Choose representative locations and depths while considering root zone, soil variability, salinity and installation contact.

Guide scope
  • Depth and sensor placement
  • Field validation and interpretation
  • Weather and irrigation context
WMO / FAO-56 contextAgriculture monitoring →
Architecture

Industrial time-series data model and naming

Preserve meaning across devices and sites with asset hierarchy, canonical units, metadata, timestamps and quality states.

Guide scope
  • Site, asset and measurement hierarchy
  • Tag naming and canonical units
  • Calibration and quality metadata
Data governanceData engineering →
Practitioner

Alarm rules, persistence and escalation

Create actionable alerts using appropriate thresholds, deadband, duration, rate-of-change, severity and response ownership.

Guide scope
  • Static and contextual thresholds
  • Persistence and nuisance reduction
  • Acknowledgement and closure workflow
No technical guides match the selected category and search phrase. Try a broader term.

Standards & reference frameworks

Use standards as engineering references—not marketing labels.

Each deployment should select the standards, manufacturer instructions, local regulations and acceptance criteria that actually apply to the asset and intended use.

ISO 17359General guidance for condition-monitoring programmes.
ISO 20816 seriesMeasurement and evaluation of machine vibration.
ISO 50001Energy management, performance and continual improvement.
IEC 60947-4-1Contactors and electromechanical motor starters.
ISO 14001Environmental-management system requirements.
ISO/IEC 17025 principlesCompetence, validity and measurement traceability.
WMO No. 8Weather instruments and observation methods.
FAO-56Crop evapotranspiration and water-requirement calculation.
i
Siteplore technical guides provide implementation guidance and do not replace approved engineering design, manufacturer requirements, competent-person review, site procedures, formal certification or regulatory obligations.

Need a guide adapted to your equipment and operating conditions?

Siteplore can convert the generic method into a site-specific measurement plan, device list, network architecture, commissioning checklist and pilot acceptance criteria.